KRN50-2000-40 - 50 mm Compact Hybrid Recorders

model * Image may differ

KRN50-2000-40

  • Power supply_AC power : 100-240VAC~ 50/60Hz
  • Input type_RTD : JPt100Ω, DPt100Ω, DPt50Ω, Cu100Ω, Cu50Ω (5 types)
  • Input type_TC : K, J, E, T, B, R, S, N, C, G, L, U, PLII (13 types)
  • Input type_Analog : · Voltage: -50.0-50.0mV, -199.0-200.0mV, -1.000-1.000V, -1.00-10.00V (4 types)
    · Current: 0.00-20.00mA, 4.00-20.00mA (2 types)
    ※ For current input, connect external 50Ω B class (0.1%) high-accuracy resistor
  • Sampling cycle : 500ms/channel×2 channels = 1000ms
  • Environment_Ambient temperature : 0 to 50℃, storage: -20 to 60℃
  • Weight : Approx. 700g (approx. 470g)
certmark certmark certmark certmark

Data sheet Print

Data sheet
Power supply_AC power 100-240VAC~ 50/60Hz
Input type_RTD JPt100Ω, DPt100Ω, DPt50Ω, Cu100Ω, Cu50Ω (5 types)
Input type_TC K, J, E, T, B, R, S, N, C, G, L, U, PLII (13 types)
Input type_Analog · Voltage: -50.0-50.0mV, -199.0-200.0mV, -1.000-1.000V, -1.00-10.00V (4 types)
· Current: 0.00-20.00mA, 4.00-20.00mA (2 types)
※ For current input, connect external 50Ω B class (0.1%) high-accuracy resistor
Communication output RS485 Communication output (ModBus RTU protocol)
Sampling cycle 500ms/channel×2 channels = 1000ms
Environment_Ambient temperature 0 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Number of input channels 2-channel
Weight Approx. 700g (approx. 470g)

※Display accuracy:
◎At room temperature (25℃±5℃)
ᆞThermocouple J (-200≤T≤-100): (±0.2% F.S. or ±2.7℃, select the higher one) ±1-digit
ᆞThermocouple R, S, C, G (0≤T≤100): (±0.2% F.S. or ±5.2℃, select the higher one) ±1-digit
ᆞThermocouple U, T (-200≤T≤-100): (±0.2% F.S. or ±3.5℃, select the higher one) ±1-digit
ᆞThermocouple U, T (-100≤T≤400): (±0.2% F.S. or ±2.5℃, select the higher one) ±1-digit
ᆞThermocouple B type, below 400℃: there is no accuracy standards.
ᆞAll thermocouples, below -100℃: (±0.4% F.S.) ±1-digit
※The weight includes packaging. The weight in parenthesis is for unit only.
※Environment resistance is rated at no freezing or condensation.