PRFDCM08-2D-IL2 - Full-Metal Cylindrical Long-Distance Inductive Proximity Sensors

PRFDCM08-2D-IL2
- Installation : Flush
- Sensing side diameter : Ø8mm
- Sensing distance : 2mm
- Hysteresis(distance) : Max. 15% of sensing distance
- Standard sensing target : 12×12×1mm(iron)
- Response frequency : 150Hz
Data sheet Print
Installation | Flush |
---|---|
Sensing side diameter | Ø8mm |
Sensing distance | 2mm |
Hysteresis(distance) | Max. 15% of sensing distance |
Standard sensing target | 12×12×1mm(iron) |
Response frequency | 150Hz |
Indicator | IO-Link mode, SIO mode |
Unit weight (packaged weight) | ≈ 10 g (≈ 35 g) |
Power supply | 10 - 30 VDC@(=)(ripple P-P: ≤ 10 %) |
Current specification | Current consumption: Max. 20mA |
Control output | Max. 100mA |
Residual voltage | ≤ 2.5 V |
Protection circuit | Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit |
Insulation resistance | ≥ 50 MΩ (500 VDC@(=) megger) |
Dielectric strength | 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) |
Vibration | 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours |
Shock | 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) |
Environment_Ambient temperature | -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) |
Environment_Ambient humidity | 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) |
Protection structure | IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 |
Connection | Connector models |
Connector type | M12 plug connector |
Material | Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303) |
※Use accessories (nut, washer) made of SUS. Or, sensing distance cannot be guaranteed.※The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.※Ambient temp.: UL approved surrounding air temperature 60 ℃※In case of SIO mode, use the device within the range where the stable indicator (green) is ON. In case of IO-Link mode, use the device within the range where unstable detection (Byte0_bit6) turns 0.
3D Viewer
* You can check out the 3D Viewer by the CAD button under the product image.
PR materials
Technical data
- No search results
-
- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}