SFLA14-31 - Safety Light Curtains (High Performance Type)
SFLA14-31
- Sensing distance : Short - Long mode (setting switch or atLightCurtain)
- Short mode : 0.2 to 5 m
- Long mode : 0.2 to 10 m
- Detection capability : Ø 14 mm (finger)
- Number of optical axes : 31
- Optical axis pitch : 9mm
- Series connection : Max. 4 SET (≤ 400 optical axes)
Data sheet Print
Sensing type | Through-beam type |
---|---|
Light source | Infrared LED(855nm) |
Effective aperture angle(EAA) | Within ± 2.5 ° when the sensing distance is greater than 3 m for both emitter and receiver. |
Sensing distance | Short - Long mode (setting switch or atLightCurtain) |
Short mode | 0.2 to 5 m |
Long mode | 0.2 to 10 m |
Detection capability | Ø 14 mm (finger) |
Sensing target | Opaque |
Protective height | 288 mm |
Number of optical axes | 31 |
Optical axis pitch | 9mm |
Series connection | Max. 4 SET (≤ 400 optical axes) |
Power supply | 24 VDC@(=) ±20 %(ripple P-P: ≤10 %) |
Current consumption | Emitter: ≤106mA, receiver: ≤181mA |
Safety related output: OSSD output | NPN or PNP open collector Load voltage : ON - 24 VDC@(=) (except for the residual voltage), OFF - 0 VDC@(=) Load current : ≤ 300 mA Residual voltage : ≤ 2 VDC@(=)(except for voltage drop due to wiring) Load capability: ≤ 2.2 ㎌ Leakage current: ≤ 2.0 mA Wire resistance of load: ≤ 2.7 Ω |
Auxiliary output(AUX 1/2) | NPN or PNP open collector Load voltage: ≤ 24 VDC@(=), Load current: ≤ 100 mA, Residual voltage: ≤ 2 VDC@(=) (except for voltage drop due to wiring) |
Lamp output(LAMP 1/2) | NPN or PNP open collectorLoad voltage: ≤ 24 VDC@(=), Load current: ≤ 300 mA |
Protection circuit | Reverse power polarity, reverse output polarity, output short-circuit over-current protection |
Safety-related functions | Interlock (reset hold), external device monitoring (EDM), muting/override, Blanking (fixed blanking, floating blanking), reduced resolution |
General functions | Self-test, alarm for reduction of incident light level, mutual interference prevention |
Others functions | Change of sensing distance, switching to NPN or PNP, external test (light emission stops), auxiliary output (AUX 1, 2), lamp output (LAMP1, 2) |
Synchronization type | Timing method by RS485 synchronous line |
Insulation resistance | Over 20MΩ (at 500VDC megger) |
Noise immunity | The square wave noise (pulse width: 1㎲) by the noise simulator ±240VDC@(=) |
Dielectric strength | 1,000VAC 50/60Hz for 1 minute |
Vibration | 10 mm double amplitude at frequency of 5 to 150 Hz, 10 sweeps ni each X, Y, Z direction |
Shock | 250 m/s² (≈ 25 G), pulse width 6 ms in each X, Y, Z direction for 100 times |
Environment_Ambient illumination | Sunlight: Max. 10,000lx, Incandescent lamp: Max. 3,000lx (received illumination) |
Ambient temperature | -30 to 60 ℃, storage: -30 ~ 70 ℃ (no freezing or condensation) |
Ambient humidity | 35 to 85 %RH, storage: 35 to 95 %RH (non-freezing or non-condensation) |
Protection structure | IP65, IP67(IEC Standard), IP67G (JEM Standard), IP69K (DIN Standard) |
Material | Case: Aluminum, Front cover and sensing part: Polymethyl methacrylate, End cap: polycarbonate, Power I/O cable and connector cable: polyurethane (PUR) or polyvinyl chloride (PVC), Y type connector cable: polyvinyl chloride (PVC), lamp output cable and series connector cable: polyurethane (PUR), Top / Bottom adjustable bracket and Top / Bottom bracket: SUS304, Side adjustable bracket and Side bracket: nickel plated Zn |
International standards | UL 508, CSA C22.2 No. 14, ISO 13849-1 (PL e, Cat. 4), ISO 13849-2 (PL e, Cat. 4), UL 61496-1 (Type 4, ESPE), UL 61496-2 (Type 4, AOPDs), IEC/EN 61496-1 (Type 4, ESPE), IEC/EN 61496-2 (Type 4, AOPDs), IEC/EN 61508-1~-7 (SIL 3), IEC/EN 62061 (SIL CL 3) |
※ Current consumption, Response time: It may differ depending on the models. For more information, see the "SFL/SFLA User Manual." ※ Load voltage of Safety related output: The values of load voltage were drawn with PNP output, and in case of NPN output, apply these in reverse. ※ Load current of Safety related output: Be sure that the load current should be greater than 6 mA ※ Residual voltage of Safety related output: The residual voltage was drawn with 300 mA of load current. ※ Auxiliary output, Lamp output: It is the non-safety output. Do not use it for safety purposes. ※ Approved certification protection ratings are IP65 and IP67. ※ The certified models for S-mark and KCs (industrial robot protection device) have the same functional basis
3D Viewer
* You can check out the 3D Viewer by the CAD button under the product image.
PR materials
Technical dataView more
- No search results
-
- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}
Related product(s)
-
LINEUP
M8/M12 Connector Cables
The M8/M12 connector cables are available in 4, 5, 8, 12-pin socket and socket-plug types for flexible application in various environment settings.
-
atLightCurtain
atLightCurtain is a dedicated software for SFL/SFLA series safety light curtains to monitor operation status and set functions Users can set various safety-related functions including muting, blanking from the parameter menu and monitor various operation status including light amount, connection, and errors. (Detailed settings may not be available on standard type SFL series)