- Sensing distance : 600 to 8000 mm
- Blind zone : 0 to 590 mm
- Foreground suppression : 600 to 1800 mm
- Max. setting zone : 8000 mm
- Transducer frequency : 80 kHz
Data sheet Print
Sensing distance | 600 to 8000 mm |
---|---|
Blind zone | 0 to 590 mm |
Foreground suppression | 600 to 1800 mm |
Max. setting zone | 8000 mm |
Transducer frequency | 80 kHz |
Switching frequency | ≥ 3 Hz |
Response time | ≤ 300 ms |
Hysteresis | 100mm |
Standard sensing target | 500 × 500 mm |
Resolution | ≥ 0.180 mm |
Power supply | 12 - 30 VDC@(=) (ripple P-P: ≤ 10 %) |
Current consumption | ≤ 80 mA (no load) |
Digital output | Push-pull |
Analog out | [voltage output] DC 0 - 10 V, [current output] DC 4 - 20 mA |
Protection circuit | Surge protection circuit, output short over current protection circuit, reverse polarity protection |
Insulation resistance | ≥ 50 MΩ (500 VDC@(=) megger) |
Dielectric strength | Between the charging part and the case: 1,000 VAC~ 50 / 60 Hz for 1 min |
Vibration | 1.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours |
Shock | 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times |
Ambient temperature | -25 to 70 ℃, storage: -40 to 85 ℃ (no freezing or condensation) |
Protection structure | IP66, IP67 (IEC standard) |
Connection | Connector models |
Connector type | M12 5-pin plug connector |
Material | Case: mount - SUS316L, body - PC, transducer: polyurethane foam, epoxy resin with glass |
Unit weight (packaged weight) | ≈210g(≈330g) |
3D Viewer
* You can check out the 3D Viewer by the CAD button under the product image.
PR materials
PR materials can be downloaded without login.
Technical data
- No search results
-
- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}