Recommended browsers

Please use Internet Explorer 10 or above for optimal viewing experience on the Autonics website.

When using Internet Explorer 10 or earlier, 3D CAD viewer and screen layout may not be displayed normally.
For ease of use the site, we recommend upgrading to a modern browser.

browser img

TMH2-22C-L - Modular Multi-Channel High Performance Temperature Controllers

model * Image may differ

TMH2-22C-L

  • No. of channel : 2-channel
  • Input type_TC : K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II
  • Input type_RTD : DPt100Ω, JPt100Ω, DPt50Ω, Cu100Ω, Cu50Ω, Nikel 120Ω 3-wire type(permissible line resistance max. 5Ω)
  • Input type_Analog : Voltage: 0-100mVDC specialstring, 0-5VDC specialstring, 1-5VDC specialstring, 0-10VDC specialstring
    Current: 0-20mA, 4-20mA
  • Input type_CT : 0.0-50.0A(primary current measurement range) ※CT ratio=1/1000, Measured accuracy: ±5% F.S. ±1-digit
  • Input type_Digital inputs : Connect input: ON - max. 1kΩ, OFF - min. 100kΩ
    Solid-state input: ON - max. residual voltage 0.9V, OFF - max. leakage current 0.5mA
    Outflow current: approx. 0.3mA per input
  • Control output_Current : Selectable DC 4-20mA or DC 0-20mA(load resistance max. 500Ω)
  • Alarm output : 250VAC~ 3A 1a
  • Communication : Modbus RTU
certmark certmark certmark certmark certmark

Data sheet Print

Data sheet
No. of channel 2-channel
Sampling cycle 50ms(2-CH or 4-CH synchronous sampling)
Input type_TC K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II
Input type_RTD DPt100Ω, JPt100Ω, DPt50Ω, Cu100Ω, Cu50Ω, Nikel 120Ω 3-wire type(permissible line resistance max. 5Ω)
Input type_Analog Voltage: 0-100mVDC specialstring, 0-5VDC specialstring, 1-5VDC specialstring, 0-10VDC specialstring
Current: 0-20mA, 4-20mA
Input type_CT 0.0-50.0A(primary current measurement range) ※CT ratio=1/1000, Measured accuracy: ±5% F.S. ±1-digit
Input type_Digital inputs Connect input: ON - max. 1kΩ, OFF - min. 100kΩ
Solid-state input: ON - max. residual voltage 0.9V, OFF - max. leakage current 0.5mA
Outflow current: approx. 0.3mA per input
Control method Heating, cooling, heating & cooling: ON/OFF, P, PI, PD, PID control
Control output_Current Selectable DC 4-20mA or DC 0-20mA(load resistance max. 500Ω)
Alarm output 250VAC~ 3A 1a
Communication Modbus RTU
Proportional band Thermocouple / RTD: 0.1 to 999.9 ℃/℉, Analog: 0.1 to 999.9 %
Integral time 0 to 9999 sec
Derivative time 0 to 9999 sec
Control period 1.0 to 120.0 sec
Manual reset 0 to 100%( 0.0 to 100.0%)
Insulation type Double insulation or reinforced insulation(mark: specialstring, dielectric strength between the measuring input part and the power part: 1kV)
Unit weight (packaged weight) ≈ 162 g (≈ 261 g)
Power supply 24VDC specialstring
Allowable voltage range 90 to 110% of rated voltage
Power consumption Max. 5W(for max. load)
Display method None-parameter setting and monitoring is available at external devices(PC, PLC, etc.)
Memory Protection ≈ 10 years (non-volatile semiconductor memory type)
Insulation resistance 100MΩ(at 500VDC megger)
Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute
Vibration 0.75 mm amplitude at frequency of 5 to 55 Hzin each X, Y, Z direction for 2 hours
Noise immunity ±0.5kV the square wave noise (pulse width: 1㎲) by the noise simulator
Environment_Ambient temperature -10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Protection structure IP20(IEC standard)