UTRCM18-350D - Cylindrical Ultrasonic Sensors

UTRCM18-350D
- Sensing distance : 30 to 350 mm
- Blind zone : 0 to 27 mm
- Foreground suppression : 30 to 90 mm
- Max. setting zone : 350 mm
- Transducer frequency : 305 kHz
Data sheet Print
Sensing distance | 30 to 350 mm |
---|---|
Blind zone | 0 to 27 mm |
Foreground suppression | 30 to 90 mm |
Max. setting zone | 350 mm |
Transducer frequency | 305 kHz |
Switching frequency | ≥ 25 Hz |
Response time | ≤ 32 ms |
Hysteresis | 3mm |
Standard sensing target | 200 × 200 mm |
Resolution | ≥ 0.069 mm |
Power supply | 12 - 30 VDC |
Current consumption | ≤ 40 mA (no load) |
Digital output | Push-pull |
Analog out | [current output] DC 4 -20 mA |
Protection circuit | Surge protection circuit, output short over current protection circuit, reverse polarity protection |
Insulation resistance | ≥ 50 MΩ (500 VDC |
Dielectric strength | Between the charging part and the case: 1,000 VAC~ 50 / 60 Hz for 1 min |
Vibration | 1.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours |
Shock | 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times |
Ambient temperature | -25 to 70 ℃, storage: -40 to 85 ℃ (no freezing or condensation) |
Protection structure | IP66, IP67 (IEC standard), IP69K (DIN standard), IP68 |
Connection | Connector models |
Connector type | M12 5-pin plug connector |
Material | Case: mount - SUS316L, body - PC, transducer: polyurethane foam, epoxy resin with glass |
Unit weight (packaged weight) | ≈ 30 g (≈ 85 g ) |
Downloads
- No search results