FXY Series - Digital Counter/Timer Indicators (Indicator Only)

FXY Series Digital Counter/Timer Indicators (Indicator Only)

The FXY series indicators are counter/timer units with counting speeds of 1 cps, 30 cps, 2 kcps, and 5 kcps and various time setting ranges. Count-up, count-down, and count up/down modes are available for accurate measurement and display of various system configurations. The FXY series is available in 4-digit and 6-digit models in standard DIN size W 72 x H 36 mm.

certmark certmark certmark certmark

Main features

  • Counting speeds : 1cps/30cps/2kcps/5kcps
  • Switch between counter and timer operation using DIP switch
  • Switch between voltage input (PNP) and no-voltage input (PNP) using DIP switch
  • Set decimal point, hr/min/sec display with RESET key
  • Operation modes : count-up, count-down, count-up/down (counter)

Counter

20 input modes

Timer

  • Various time setting ranges
    • - 6-digit models : 0.01sec to 99999.9hr
    • - 4-digit models : 0.01sec to 9999hr
  • Power supply
    • - 100-240 VAC 50/60 Hz (AC type)
    • - 24 VAC 50/60 Hz, 24-48 VDC (AC/DC universal type)

Model Change

Model Change detail
Type 4-Digit (Indicator Only) 6-Digit (Indicator Only)
Previous Upgrade Previous Upgrade
AC Type FX4Y-I FX4Y-I FX6Y-I FX6Y-I4
AC/DC Type FX4Y-I FX4Y-I2 FX6Y-I FX6Y-I2

4-Digit (Indicator Only)

Previous
4-Digit (Indicator Only) Previous detail
AC Type FX4Y-I
AC/DC Type FX4Y-I
Upgrade
4-Digit (Indicator Only) Upgrade detail
AC Type FX4Y-I4
AC/DC Type FX4Y-I2

6-Digit (Indicator Only)

Previous
6-Digit (Indicator Only) Previous detail
AC Type FX6Y-I
AC/DC Type FX6Y-I
Upgrade
6-Digit (Indicator Only) Upgrade detail
AC Type FX6Y-I4
AC/DC Type FX6Y-I2

Design

Ordering Information

Previous : FXY Series

Previous : FXY Series
I (Output) Indicator
Y (Size) DIN W72 x H36mm
4 (digit) 9999 (4-digit)
6 (digit) 999999 (6-digit)
FX (Item) Counter/Timer

Upgrade : FXY Series

Upgrade : FXY Series
Model Display digit Size Output Power supply
FX4Y-I2 9999 (4-digit) DIN W72 x H36mm Indicator 24VAC 50/60Hz, 24-48VDC
FX4Y-I4 100-240VAC 50/60Hz
FX6Y-I2 999999 (6-digit) 24VAC 50/60Hz, 24-48VDC
FX6Y-I4 100-240VAC 50/60Hz

*New model names to Indicate power supply type

Power Supply

Previous : FXY Series

Previous Power Supply detail
Power supply AC power 100-240VAC 50/60Hz
AC/DC power 12-24VAC 50/60Hz, 12-24VDC

Upgrade : FXY Series

Upgrade Power supply detail
Model Indicator FX4Y-I2 FX4Y-I4 FX6Y-I2 FX6Y-I4
Power supply 24VAC-50/60Hz, 24-48VDC= 100-240VAC-50/60Hz 24VAC-50/60Hz, 24-48VDC= 100-240VAC-50/60Hz

New power supply range for AC/DC type models

  • - Previous : 12-24VAC 50/60Hz, 12-24VDC
  • - Upgrade : 24VAC 50/60Hz, 24-48VDC

Power Consumption

Previous : FXY Series

Previous Power Consumption detail
Power consumption AC power Max. 4.5VA (100-240VAC 50/60Hz)
AC/DC power Max. 4.5VA (100-240VAC 50/60Hz), Max. 2.8W (12-24VDC)

Upgrade : FXY Series

Upgrade Power Consumption detail
Model Indicator FX4Y-I2 FX4Y-I4 FX6Y-I2 FX6Y-I4
Power consumption Max. 2.8VA (24VAC-50/60Hz), Max. 1.8W (24-48VDC=) Max. 3.8VA (240VAC-50/60Hz), Max. 1.8W (24-48VDC=) Max. 2.8VA (24VAC-50/60Hz), Max 1.8W (24-48VDC=) Max. 3.8VA (240VAC-50/60Hz)

Reduced power consumption

Input (Added Voltage Input)

Previous : FXY Series

Previous Input detail
No-Voltage (NPN) Input
  • Short-Circuit Impedance : Under 470Ω
  • Short-Circuit Residual Voltage : Under 1VDC
  • Open-Circuit Impedance : Over 100 kΩ

Upgrade : FXS Series

Upgrade Input detail
Voltage (PNP) Input
  • Input Impedance : 10.8kΩ
  • High-Level Voltage : 5-30VDC
  • Low-Level Voltage : 0-2VDC
No-Voltage (NPN) Input
  • Short-Circuit Impedance : Under 470Ω
  • Short-Circuit Residual Voltage : Under 1VDC
  • Open-Circuit Impedance : Over 100kΩ

Added voltage input (PNP) method

Certifications

Dimensions

Bracket

Connection Diagram

Previous : FXY Series

It can be selected reset or sensor power (+12VDC 50mA) by controlling inner jump pin.

Upgrade : FXY Series

Changed and added terminal (6→7)

Previous : The unit required using the jumper pin inside the cover to reset the unit or select sensor power supply

SOURCE, RESET detail
Type Previous Upgrade
SOURCE 5, 6 6, 7
RESET - 5

DIP Switch Arrangement

Switch Arrangement

Switch Arrangement detail
Function Previous Upgrade
Use Front RESET key (ON/OFF) 8 7
Memory protection (ON/OFF) 9 8
Counter/timer mode 10 9
Input logic (NPN/PNP) - 10

Decimal Point/Hr/Min/Sec Display

Previous : FXY Series

* Previous models do not contain decimal point function, hr. min. sec. display function

Upgrade : FXY Series

In run mode, hold the RESET key for over 3 sec and it enters setting mode dp

In setting mode, hold the RESET key for over 3 sec, and it saves the setting and returns to RUN mode.

If there is no RESET key input for 60 sec when entering setting mode. It returns to RUN mode.

Added decimal point function during counter operation

Added hr/min/sec display function during timer operation

Downloads

  • No search results

Model Finder

Please use the model finder to search for products using detailed specifications Model Finder

Recently viewed product(s)

View more

There are no recently viewed product(s)

Interested product(s)

View more

Compare products

View more

Download history

View more

Product Inquiry