■ Advanced unit-Safety door lock switch, Expansion relay unit
Connection Examples
Connections
Start
PL/Safety category
Safety controller: Advanced unit SFC-A Series Safety door lock switch: SFDL Series Safety limit switch (from Annex C of ISO 13849-1) Safety emergency stop button switch: SF2ER Series Push button switch (from Annex C of ISO 13849-1) Contactor of rated load (from Annex C of ISO 13849-1)
Manual
PLe/Cat.4 equivalent
Safety controller: Expansion relay unit SFC-ER Series Contactor of rated load (from Annex C of ISO 13849-1)
-
When you do not use the logic input (M61, M62), set the switch of the logic (AND) input (SW1, SW2) to OFF.
Set the switches for off-delay time on the front and back of the advanced unit to the same.
Be sure to supply suitable DC or AC to the MC5 and MC6.
■ Non-contact door switch unit-Safety non-contact door switch
Connection Examples
Connections
Start
PL/Safety category
Safety controller: Non-contact door switch unit SFC-N Series Safety emergency stop button switch: SF2ER Series Safety limit switch (from Annex C of ISO 13849-1) Push button switch (from Annex C of ISO 13849-1) Safety non-contact door switch: SFN Series Contactor of rated load (from Annex C of ISO 13849-1)
Auto
PLd/Cat.3 equivalent
For more information on detailed wiring for safety non-contact door switch (SFN Series), refer to the “Instruction manual for SFN .” When you do not use the logic input (M61, M62), set the switch of the logic (AND) input (SW1, SW2) to OFF. Set the switches for off-delay time on the front and back of the non-contact switch unit to the same.
■ Basic unit-Safety emergency stop switch, Non-contact door switch unit-Safety non-contact door switch
Connection Examples
Connections
Start
PL/Safety category
Safety controller: Basic unit SFC Series Safety emergency stop button switch: SF2ER Series Push button switch (from Annex C of ISO 13849-1) Contactor of rated load (from Annex C of ISO 13849-1)
Manual
PLd/Cat.3 equivalent
Safety controller: Non-contact door switch unit SFC-N Series Push button switch (from Annex C of ISO 13849-1) Safety light curtain: SFL / SFLA Series Safety non-contact door switch: SFN Series Contactor of rated load (from Annex C of ISO 13849-1)
Auto
For more information on detailed wiring for safety non-contact door switch (SFN Series), refer to the “Instruction manual for SFN .”
For more information on wiring and detailed settings for safety light curtain (SFL/SFLA Series), refer to “SFL/SFLA user manual. ”
The control output of the safety light curtain (SFL(A) series) is based on the PNP output.
When you use the logic input (M61, M62), set the switch of the logic (AND) input (SW1, SW2) to ON.
Set the switches for off-delay time on the front and back of the non-contact switch unit to the same.
Safety controller: Relay unit SFC-R212 Safety emergency stop button switch: SF2ER Series Push button switch (from Annex C of ISO 13849-1) Contactor of rated load (from Annex C of ISO 13849-1)
Manual
PLe/Cat.4 equivalent
When you do not use the logic input (M61, M62), set the switch of the logic (AND) input (SW1, SW2) to OFF. Set the switches for off-delay time on the front and back of the relay unit to the same.
Safety controller: Relay unit SFC-R212-R2□□ Safety door lock switch: SFDL Series Push button switch (from Annex C of ISO 13849-1) Contactor of rated load (from Annex C of ISO 13849-1)
Manual
PLe/Cat.4 equivalent
Set the switches for off-delay time on the front and back of the relay unit to the same.